BGRKG - 27-128-01,AQUATEST 8 REAGENT,GENERATOR SOLU

  • MSDS: BGRKG
  • Manufacturer: SERAGEN DIAGNOSTICS INC
  • Product Name: 27-128-01,AQUATEST 8 REAGENT,GENERATOR SOLU
  • National Stock Number: 6630-01-253-3825
Product Identification

Product ID:27-128-01,AQUATEST 8 REAGENT,GENERATOR SOLU
MSDS Date:03/15/1991
FSC:6630
NIIN:01-253-3825
Kit Part:Y
MSDS Number: BGRKG

Responsible Party
SERAGEN DIAGNOSTICS INC.
1200 MADISON AVE
INIANAPOLIS, IN 46206
US

Emergency Phone: 317-266-2080

Info Phone: 800-222-5711

Cage: DO636

Contractor
SERAGEN DIAGNOSTICS
1210 INDIANAPOLIS, IN 46206 US

Telephone: 317-266-2080

Cage: DO636

Ingredients

2-METHOXYETHANOL (EGME) (SARA III)

CAS: 109-86-4

RTECS: KL5775000

Fraction By Weight: 73%

OSHA PEL S, 25 PPM

ACGIH TLV: S, 5 PPM; 9192


IODINE

CAS: 7553-56-2

RTECS: NN1575000

Fraction By Weight: 15%

OSHA PEL C 0.1 PPM

ACGIH TLV: C 0.1 PPM; 9192


SULFUR DIOXIDE

CAS: 7446-09-5

Fraction By Weight: 12%

OSHA PEL 5 PPM/5 STEL

ACGIH TLV: 2 PPM/5 STEL; 9293

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:COMPONENTS ARE IRRITATING TO
EYES,SKIN,ETC. 2-METHOXYETHANOL PRODUCES CNS EFFECTS BY INHALATION
OR SKIN ABSSORPRTION. CHRONIC OVEREXPOSURE: DRY CRACKED SKIN,
CENTRAL NERVOUS SYSTEM EFFECTS, POSSIBLE S TERILITY
Explanation of Carcinogenicity:THE PRODUCT CONTAINS NO INGREDIENT THAT
IS LISTED BY IARC, NTP OR OSHA AS A CARCINOGEN.
Effects of Overexposure:EYES:IRRITATION SKIN:IRRITATION, CENTRAL
NERVOUS SYSTEM EFFECTS IF ABSORBED THROUGH SKIN. INHALED:
DIZZINESS,NAUSEA,HEADACHE. INGESTED: G/I IRRITATION AND
DISTRESS,MAUSEA VOMITING. LETHARGY, CONFUSION ,NARCOSIS. HIGH
CRONIC EXPOSURE MAY LEADTO CNS DEPRESSION, POSSIBLE STERILITY.
Medical Cond Aggravated by Exposure:MANUFACTURER REPORTS, "NONE KNOWN'.

First Aid

First Aid:EYES:FLUSH WITH WATER 15 MIN. SKIN: IMMEDIATELY WASH WITH
SOAP/WATER. REMOVE CONTAMINATED CLOTHING AND LAUNDER BEFORE REUSE.
INHALE: REMOVE TO FRESH AIR.GIVE OXYGEN OR CPR AS NEEDED. CALL A
PHYSICIAN. INGESTED: MFR REPORTS "NO DATA AVAILABLE". HMIS:DO NOT
INDUCE VOMITING. CALL PHYSICIAN IMMEDIATELY. FOR ANY EXPOSURE
INVOLVING A SIGNIFICANT AMOUNT OF MATERIAL, GET MEDICAL ASSISTANCE.

Fire Fighting

Flash Point Method:CC
Flash Point:102F,39C
Extinguishing Media:ALCOHOL FOAM, CARBON DIOXIDE,DRY CHEMICAL,WATER
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:MAY EMIT TOXIC FUMES IN A FIRE.

Accidental Release

Spill Release Procedures:ELIMINATE SOURCES OF IGNITION. USE PROTECTIVE
EQUIPMENT APPROPRIATE FOR TASK. ABSORB ON INERT MATERIAL. COLLECT
IN CLOSED CONTAINER.
Neutralizing Agent:NONE

Handling

Handling and Storage Precautions:STORE STANDARD FLAMMABLE LIQUID
STORAGE CABINET. KEEP TIGHTLY CLOSED.

Exposure Controls

Respiratory Protection:RESPIRATOR WILL NOT NORMALLY BE NECESSARY. USE
NIOSH/MSHA APPROVED AIR SUPPLIED RESPIRATOR OR RESPIRATOR FOR
ORGANIC VAPOR IF EXPOSURE IS ABOVE THE TLV/PEL. SEE 29 CFR 1910.134
FOR REGULATIONS PERTAI NING TO RESPIRATOR USE.
Ventilation:NOT NORMALLY REQUIRED. USE LAB HOOD OR OTHER LOCAL EXHAUST
TO MAINTAIN EXPOSURE BELOW PEL/TLV.
Protective Gloves:RUBBER/PLASTIC
Eye Protection:SAFETY GLASSES/SPLASH GOGGLES
Other Protective Equipment:SAFETY SHOWER/EYE WASH, LAB COAT OR APRON.
USE ADDITIONAL IMPERVIOUS CLOTHING AS NEEDED TO PREVENT SKIN
CONTACT.
Work Hygienic Practices:USE GOOD CHEMICAL HYGIENE PRACTICE. AVOID
UNNECESSARY CONTACT. WASH THOROUGHLY BEFORE EATING OR DRINKING.
Supplemental Safety and Health
THIS ENTRY DESCRIBES:27-128-01, GENERATOR SOLUTION WHICH IS A PART OF
THE KIT; SEE ADDITIONAL DATA FOR MORE INFORMATION;KEY1:F4 MSDS
RECEIVED FROM NAVY (FOCAL POINT N).

Chemical Properties

HCC:F2
Spec Gravity:>1.0
Solubility in Water:SLIGHTLY SOLUBLE
Appearance and Odor:CLEAR DARK BROWN LIQUID, SULFUL DIOXIDE ODOR
Percent Volatiles by Volume:85

Stability

Stability Indicator/Materials to Avoid:YES
WATER, REACTIVE METALS, STRONG OXIDIZERS, CHLORATES, CARBIDES
Stability Condition to Avoid:HEAT, IGNITION SOURCES, MOISTURE
Hazardous Decomposition Products:IODINE FUMES, SULFUR OXIDES, CARBON
OXIDES

Disposal

Waste Disposal Methods:DISPOSE I/A/W ALL FEDERAL, STATE AND LOCAL
REGULATIONS. MANUFACTURER MAKES NO SUGGESTIONS AS TO METHOD OF
DISPOSAL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.